Commissioning of the Treatment Planning System RayStation at the Heidelberg Ion-Beam Therapy Center

Commissioning of the Treatment Planning System RayStation at the Heidelberg Ion-Beam Therapy Center
Author: Benedikt Kopp
Publisher:
Total Pages:
Release: 2017
Genre:
ISBN:

Download Commissioning of the Treatment Planning System RayStation at the Heidelberg Ion-Beam Therapy Center Book in PDF, Epub and Kindle

The Heidelberg Ion-Beam Therapy Center (HIT) uses the Raster Scan technique for proton and carbon ions. The treatment planning system (TPS) RayStation, Raysearch Laboratories, will be integrated into the application system IONTRIS, Siemens Healthineers.As TPS commissioning for proton and carbon ions various cases of target volumes were optimized with the clinical TPS Syngo RT Planning, Siemens Healthineers, using a Pencil Beam (PB) algorithm. Dose distributions rising from simple geometries like cubic volumes in water to complex cases like anthropomorphic Rando Alderson head phantom and double-wedge phantom were recalculated in RayStation using a PB algorithm for Carbons and Monte Carlo (MC) for Protons. RayStation dose distributions were compared with syngo TPS calculations and to measurements with a 24 Pin-Point chamber array in a water phantom and for complex geometries with the 2D array Octavius1000SRS, both PTW.For Protons both TPS were comparable for simple geometries. The RayStation MC algorithm better describes the lateral spread of the proton beam passing a range modulator and an air gap of 20 cm. For complex geometries, including cases with lateral inhomogeneities or oblique entrance, the RayStation MC shows better agreement with the measurements. The carbon PB calculation is on the same level of precision as the Syngo TPS for all geometries.Still based on preliminary basis data, the RayStation dose calculation yields excellent results. We are looking forward to integrating RayStation into clinical routine and making use of its powerful tools.


Commissioning of the Treatment Planning System RayStation at the Heidelberg Ion-Beam Therapy Center
Language: en
Pages:
Authors: Benedikt Kopp
Categories:
Type: BOOK - Published: 2017 - Publisher:

GET EBOOK

The Heidelberg Ion-Beam Therapy Center (HIT) uses the Raster Scan technique for proton and carbon ions. The treatment planning system (TPS) RayStation, Raysearc
Exploring RayStation Treatment Planning System
Language: en
Pages: 76
Authors: Jui Wan
Categories:
Type: BOOK - Published: 2017 - Publisher:

GET EBOOK

RayStation, a new treatment planning system (TPS), was purchased and recently commissioned for clinical use by the institution. As part of the commissioning pro
Commissioning and Clinical Implementation of a New 3D Computerized Radiation Treatment Planning System
Language: en
Pages: 380
Authors: Serban Morcovescu
Categories: Electron beams
Type: BOOK - Published: 2003 - Publisher:

GET EBOOK

Current Status and Future Prospects of Carbon-Ion Therapy Facility Project of Yamagata University
Language: en
Pages:
Authors: Yoshiro Ieko
Categories:
Type: BOOK - Published: 2017 - Publisher:

GET EBOOK

Construction of seventh carbon-ion therapy facility in Japan, East Japan Heavy Ion Center, Faculty of Medicine, Yamagata University, is near completion. The bui
Raster-scanning Helium Ion Beam Therapy: Development and Validation of a Novel Treatment Planning System for Biophysical Modeling and Optimization
Language: en
Pages:
Authors: Andrea Mairani
Categories:
Type: BOOK - Published: 2017 - Publisher:

GET EBOOK

Since 2009, over 5000 patients have been treated with proton (1H) and carbon (12C) ion beams at the Heidelberg Ion Therapy Center (HIT). By 2020, HIT will begin